Modification History
Release |
Action |
Core/Elective |
Details |
Points |
2 |
Update |
Group A |
HLTCPR211A Perform CPR |
10 |
3 |
Update |
Elective |
HLTAID001 - Provide cardiopulmonary resuscitation |
10 |
3 |
Edit |
Core |
Correct title of UEENEEK142A - Apply environmentally and sustainable procedures in the energy sector |
20 |
3 |
Edit |
Core |
Correct title of UEENEEE102A - Fabricate, assemble and dismantle utilities industry components |
40 |
3 |
Edit |
Elective |
Correct title of UEENEEK117A - Maintain and repair facilities associated with remote area essential service operations |
120 |
Description
Scope
This qualification provides competencies in routine maintenance of remote area power supplies consisting of battery banks, generator sets, photovoltaic arrays and wind generators. Primarily for use by, but not exclusive to, indigenous communities.
Pathways Information
Not applicable.
Licensing/Regulatory Information
Not applicable.
Entry Requirements
Not applicable.
Employability Skills Summary
Not applicable.
Packaging Rules
Completion requirements
The requirements for granting this qualification will be met when competency is demonstrated and achieved for:
- All the Core competency standard units, defined in the Core Competency Standard Units table below and
- A combination of Elective competency standard units to achieve a total weighting of 160 points in accordance with the Elective Competency Standard Units table below.
Core Competency Standard Units All Core competency standard units to be achieved |
Weighting Points |
|
UEENEEE038B |
Participate in development and follow a personal competency development plan |
20 |
UEENEEE101A |
Apply Occupational Health and Safety regulations, codes and practices in the workplace |
20 |
UEENEEE102A |
Fabricate, assemble and dismantle utilities industry components |
40 |
UEENEEE103A |
Solve problems in ELV single path circuits |
40 |
UEENEEE137A |
Document and apply measures to control OHS risks associated with electrotechnology work |
20 |
UEENEEK101A |
Maintain safety and tidiness of remote area power supply systems |
20 |
UEENEEK102A |
Work safely with remote area power supply systems |
20 |
UEENEEK142A |
Apply environmentally and sustainable procedures in the energy sector |
20 |
Total points in core |
200 |
Elective Competency Standard Units Complete Elective units to achieve a total of weighting of 160 points from the following groups: |
|||
Group |
Minimum points |
Maximum points |
|
A |
Imported and Common Elective Units Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 2. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points. |
0 |
60 |
B |
Qualification Elective Units You may select all your elective units from this Group |
100 |
160 |
Group A – Imported and Common Elective Units You may complete units to a maximum weighting of 60 |
Weighting Points |
|
UEENEEC001B |
Maintain documentation |
20 |
UEENEEC002B |
Source and purchase material/parts for installation or service jobs |
20 |
UEENEEC008B |
Receive and store materials and equipment for electrotechnology work |
20 |
UEENEEC010B |
Deliver a service to customers |
20 |
UEENEEE020B |
Provide basic instruction in the use of electrotechnology apparatus |
20 |
CPCCOHS1001A |
Work safely in the construction industry |
10 |
HLTAID001 |
Provide cardiopulmonary resuscitation |
10 |
Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 2. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points. Note: For further information see Application of the NQC Flexibility Formula, UEE11 Electrotechnology Training Package, Version 1, Volume 1 Qualification Framework |
Up to 60 points |
|
Group B – Qualification Elective Units Complete units to a minimum weighting of 100 You may select all your elective units from this Group |
Weighting Points |
|
UEENEEE107A |
Use drawings, diagrams, schedules, standards, codes and specifications |
40 |
UEENEEK103A |
Conduct periodic maintenance of remote area power supply battery banks |
40 |
UEENEEK104A |
Conduct periodic maintenance of remote area power supply generator sets |
40 |
UEENEEK105A |
Conduct periodic maintenance of remote area power supply photo voltaic arrays |
40 |
UEENEEK106A |
Conduct periodic maintenance of remote area power supply wind generators |
40 |
UEENEEK111A |
Assemble and connect remote area power supplies |
60 |
UEENEEK112A |
Provide basic sustainable energy solutions for energy reduction in residential premises |
40 |
UEENEEK114A |
Promote sustainable energy practices in the community |
40 |
UEENEEK116A |
Maintain and repair remote area power generation facilities |
120 |
UEENEEK117A |
Maintain and repair facilities associated with remote area essential service operations |
120 |
Note:
1. Prerequisite pathways shall be identified and met for all elective units selected.
2. In selecting elective units considerations to career planning advice should be given to units that form part of a prerequisite pathway for the progression to achieve particular competencies or qualification at a higher level.
END OF QUALIFICATION